4 research outputs found

    Cuantificación automática de lesión ocupante de espacio a partir de tomografía computarizada contrastada del abdomen

    Get PDF
    Space-occupying lessions represent a healt higt risk of subjects affected by this kind of pathology. From a medical point of view, the volume occupied by each of these lesions constitutes the most important descriptor when addressing them, and especially for the respective decision-making process that guides their control, mitigation or elimination. In such context, this paper proposes a strategy based on computer-aided image processing techniques to extract the three-dimensional morphology of a space-occupying lesion, of the amoebic liver abscess type, and calculate its volume. In this sense, in order to attenuate poissonian noise and improve the abscess edge information, the abdominal contrast computed tomography images are preprocessed using a Gaussian filter, and edge detector and a median filter, sequentially. Then, a clustering algorithm based on region growing procedure is applied to the enhanced images, obtaining the space occupying lesion three-dimensional shape. Additionally, the Dice coefficient is considered as a metric to establish the correlation between the shapes, automatic and manual lesion, the latter described by a mastologist. Then, in order to characterize the liver abscess, its volume is quantified considering both the voxels occupied by the lesion obtained by applying of the computer-aided image processing, and the physical dimensions of the voxel. Finally, the automatically calculated volume is compared to that generated manually by the medical specialist. The results reveal an excellent correspondence between manual results and those produced by the proposed technique. This type of technique can be used as a resource not only to obtain, precisely, the value of the aforementioned descriptor, but also to monitor the process of the abscess evolution by means imaging control.Las lesiones que ocupan espacio representan un alto riesgo para la salud de los sujetos afectados por este tipo de patología. Desde el punto de vista médico, el volumen ocupado por cada una de estas lesiones constituye el descriptor más importante al abordarlas, y especialmente para el respectivo proceso de toma de decisiones que guía su control, mitigación o eliminación. En este contexto, este artículo propone una estrategia basada en técnicas de procesamiento de imágenes asistidas por computadora para extraer la morfología tridimensional de una lesión que ocupa espacio, del tipo de absceso hepático amebiano, y calcular su volumen. En este sentido, para atenuar el ruido poissoniano y mejorar la información del borde del absceso, las imágenes de tomografía computarizada de contraste abdominal se preprocesan utilizando un filtro gaussiano, un detector de borde y un filtro de mediana, secuencialmente. Luego, se aplica un algoritmo de agrupamiento basado en el procedimiento de crecimiento de regiones a las imágenes mejoradas, obteniendo la forma tridimensional de la lesión que ocupa espacio. Además, el coeficiente Dice se considera como una métrica para establecer la correlación entre las formas, lesión automática y manual, la última descrita por un mastólogo. Luego, para caracterizar el absceso hepático, su volumen se cuantifica considerando tanto los voxeles ocupados por la lesión obtenida mediante la aplicación del procesamiento de imágenes asistido por computadora, como las dimensiones físicas del voxel. Finalmente, el volumen calculado automáticamente se compara con el generado manualmente por el médico especialista. Los resultados revelan una excelente correspondencia entre los resultados manuales y los producidos por la técnica propuesta. Este tipo de técnica puede usarse como un recurso no solo para obtener, precisamente, el valor del descriptor mencionado anteriormente, sino también para monitorear el proceso de evolución del absceso mediante el control de imágenes

    Esquemas de registro para alinear imágenes del cerebro

    Get PDF
    In this paper, the results obtained by the registration process of brain image volumes obtained by magnetic resonance imaging (MRI) and functional magnetic resonance imaging (MRI) using two different computational frameworks are presented. The objective is to compare the performance of each framework, focusing this comparison in the error measurement obtained by brain volumes registration. The comparison involves the intra patient and intra modality (MRI-MRI and fMRI-fMRI) registration. Statistical Parametric Mapping (SPM) and Insight Segmentation and Registration Toolkit (ITK) are chosen as registration frameworks. The proposed methodology considers the data sets generation, test planning, designing test cases, tests execution and evaluating. Finally, these results are analysed. The correspondence between the volumes registered and the target volume using the ITK framework is greater than that obtained with the SPM framework.En este artículo, se presentan los resultados obtenidos por el proceso de registro de los volúmenes de imágenes cerebrales obtenidos por resonancia magnética (MRI) y resonancia magnética funcional (fMRI) utilizando dos marcos computacionales diferentes. El objetivo es comparar el rendimiento de cada marco, enfocando esta comparación en la medición de error obtenida por el registro de volúmenes cerebrales. La comparación involucra el registro intramodal e intramodalidad (MRI-MRI y fMRI-fMRI). El Statistical Parametric Mapping (SPM) y el Insight Segmentation and Registration Toolkit (ITK) se eligen como marcos de registro. La metodología propuesta considera la generación de conjuntos de datos, planificación de pruebas, diseño de casos de prueba, ejecución de pruebas y evaluación. Finalmente, estos resultados son analizados. La correspondencia entre los volúmenes registrados y el volumen objetivo usando el marco ITK es mayor que la obtenida con el marco SPM

    Registration frameworks for aligning brain images

    No full text
    In this paper, the results obtained by the registration process of brain image volumes obtained by magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) using two different computational frameworks are presented. The objective is to compare the performance of each framework, focusing this comparison in the error measurement obtained by brain volumes registration. The comparison involves the intra patient and intra modality (MRI–MRI and fMRI–fMRI) registration. Statistical Parametric Mapping (SPM) and Insight Segmentation and Registration Toolkit (ITK) are chosen as registration frameworks. The proposed methodology considers the data sets generation, test planning, designing test cases, tests execution and evaluating. Finally, these results are analysed. The correspondence between the volumes registered and the target volume using the ITK framework is greater than that obtained with the SPM framework

    Registration frameworks for aligning brain images

    No full text
    In this paper, the results obtained by the registration process of brain image volumes obtained by magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) using two different computational frameworks are presented. The objective is to compare the performance of each framework, focusing this comparison in the error measurement obtained by brain volumes registration. The comparison involves the intra patient and intra modality (MRI–MRI and fMRI–fMRI) registration. Statistical Parametric Mapping (SPM) and Insight Segmentation and Registration Toolkit (ITK) are chosen as registration frameworks. The proposed methodology considers the data sets generation, test planning, designing test cases, tests execution and evaluating. Finally, these results are analysed. The correspondence between the volumes registered and the target volume using the ITK framework is greater than that obtained with the SPM framework
    corecore